Wishlist Quick view Danfoss 131H9930 Danfoss Danfoss, Vlt Hvac Drive, Fc 100, 45 Kw, 60 Hp, 90 A, Three Phases, Ip20 / Chassis, Class A1/b1, No Brake Chopper, Graphical Local Control Panel, Coated Pcb, No Mains Option Danfoss 131H9930 Danfoss New replacements for discontinued Danfoss drives Add to Wishlist
Wishlist Quick view Danfoss 131H9968 Danfoss Vlt Automationdrive Fc 302 3kw Inverter Drive 7.2 A, Three Phase With A 380...480v Ac Supply Fc-302p3k0t5e20h2xgxxxxsxxxxa4bxcxxxxdx Danfoss 131H9968 Mains supply Supply voltage 380...480V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist
Wishlist Quick view Danfoss 131L0164 Danfoss Vlt Automationdrive Fc 302 37kw Inverter Drive 73 A, Three Phase With A 380...480v Ac Supply Fc-302p37kt5e20h1bgxdxxsxxxxaxbxc4xxxd0 Danfoss 131L0164 Mains supply Supply voltage 380...480V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist
Wishlist Quick view Danfoss 131L0208 Danfoss Vlt Hvac Drive 4kw Inverter Drive, 10a, Three Phase With A 380...480v Ac Supply Fc-102p4k0t4e55h3xgxxxxsxxxxaxb0cxxxxdx Danfoss 131L0208 Mains supply Supply voltage 380...480V AC Supply frequency 50/60 Hz Displacement power factor (cos φ) near unity (>0.98) Switching on input supply 1-2 times/min ... Add to Wishlist
Wishlist Quick view Danfoss 131L0212 Danfoss Vlt Aqua Drive 132kw Inverter Drive 260a, Three Phase With A 380...480v Ac Supply Fc-202p132t4e00h4tgx7xxsxxxxaxbxcxxxxdx Danfoss 131L0212 Mains supply Supply voltage 380...480V AC Supply frequency 50/60 Hz Displacement power factor (cos φ) near unity (>0.98) Switching on input supply 1-2 times/min ... Add to Wishlist
Wishlist Quick view Danfoss 131L0233 FC-202P75KT4E66H2XGCXXXSXXXXAXBXCXXXXDX FC-202P75KT4E66H2XGCXXXSXXXXAXBXCXXXXDXFrequency converterFC-202P75KT4E66H2XGCXXXSXXXXAXBXCXXXXDXVLT® AQUA Drive FC-202(P75K) 75 KW / 100 HP, Three phase380 - 480 VAC, (E66) IP66 / NEMA 4XRFI... Add to Wishlist
Wishlist Quick view Danfoss 131L0234 FC-202P3K0T4E66H2XGCXXXSXXXXAXBXCXXXXDX FC-202P3K0T4E66H2XGCXXXSXXXXAXBXCXXXXDXFrequency converterFC-202P3K0T4E66H2XGCXXXSXXXXAXBXCXXXXDXVLT® AQUA Drive FC-202(P3K0) 3.0 KW / 4.0 HP, Three phase380 - 480 VAC, (E66) IP66 / NEMA 4XRFI... Add to Wishlist
Wishlist Quick view Danfoss 131L0252 FC-202P30KT4E20H3XGCXXXSXXXXAXBKCXXXXDX FC-202P30KT4E20H3XGCXXXSXXXXAXBKCXXXXDXFrequency converterFC-202P30KT4E20H3XGCXXXSXXXXAXBKCXXXXDXVLT® AQUA Drive FC-202(P30K) 30 KW / 40 HP, Three phase380 - 480 VAC, (E20) IP20 / Chassis(H3) RFI... Add to Wishlist
Wishlist Quick view Danfoss 131L0285 FC-202P37KT4E55H1XGCXXXSXXXXAXBKCXXXXDX FC-202P37KT4E55H1XGCXXXSXXXXAXBKCXXXXDXFrequency converterFC-202P37KT4E55H1XGCXXXSXXXXAXBKCXXXXDXVLT® AQUA Drive FC-202(P37K) 37 KW / 50 HP, Three phase380 - 480 VAC, IP55 / Type 12(H1) RFI Class... Add to Wishlist
Wishlist Quick view Danfoss 131L0297 Danfoss Vlt Aqua Drive 3kw Inverter Drive 7.2a, Three Phase With A 380...480v Ac Supply Fc-202p3k0t4e66h2xxxxxxsxxxxaxbxcxxxxdx Danfoss 131L0297 Mains supply Supply voltage 380...480V AC Supply frequency 50/60 Hz Displacement power factor (cos φ) near unity (>0.98) Switching on input supply 1-2 times/min ... Add to Wishlist
Wishlist Quick view Danfoss 131L0463 FC-202P75KT4E20H1XGXXXXSXXXXAXB0CXXXXDX FC-202P75KT4E20H1XGXXXXSXXXXAXB0CXXXXDXFrequency converterFC-202P75KT4E20H1XGXXXXSXXXXAXB0CXXXXDXVLT® AQUA Drive FC-202(P75K) 75 KW / 100 HP, Three phase380 - 480 VAC, (E20) IP20 / Chassis(H1) RFI... Add to Wishlist
Wishlist Quick view Danfoss 131L0486 Danfoss Vlt Automationdrive Fc 302 30kw Inverter Drive 41 A, Three Phase With A 500...575v Ac Supply Fc-302p30kt6e55hxxgxxxxsxxxxa0bxcxxxxd0 Danfoss 131L0486 Mains supply Supply voltage 500...575V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist
Wishlist Quick view Danfoss 131L0492 Danfoss Vlt Automationdrive Fc 302 4kw Inverter Drive A, Three Phase With A 500...575v Ac Supply Fc-302p4k0t6e55hxxgxxxxsxxxxa0bxcxxxxd0 Danfoss 131L0492 Mains supply Supply voltage 500...575V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist
Wishlist Quick view Danfoss 131L0494 Danfoss Vlt Automationdrive Fc 302 7.5kw Inverter Drive A, Three Phase With A 500...575v Ac Supply Fc-302p7k5t6e55hxxgxxxxsxxxxa0bxcxxxxd0 Danfoss 131L0494 Mains supply Supply voltage 500...575V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist
Wishlist Quick view Danfoss 131L0495 Danfoss Vlt Automationdrive Fc 302 11kw Inverter Drive 18 A, Three Phase With A 500...575v Ac Supply Fc-302p11kt6e55hxxgxxxxsxxxxa0bxcxxxxd0 Danfoss 131L0495 Mains supply Supply voltage 500...575V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist
Wishlist Quick view Danfoss 131L0498 Danfoss Vlt Automationdrive Fc 302 18.5kw Inverter Drive 27 A, Three Phase With A 500...575v Ac Supply Fc-302p18kt6e55hxxgxxxxsxxxxa0bxcxxxxd0 Danfoss 131L0498 Mains supply Supply voltage 500...575V AC Supply frequency 50/60 Hz True Power Factor (λ) 0.92 nominal at rated load Displacement Power Factor (cos φ) near... Add to Wishlist